Gas Relay
- Details
Gas relay sedrles QJ are kinds of protective devices installed on oil immersed transformers with on load tap changers of 800KVA and above, it is mocented on the connecting pipe between transformer and oil conservator. When the stop plate of gas relay is rushed by gas or heavy oil flow caused by internal failure of transformer or on load tap changer,the tripping contacts will be closed and the power source be disconnected automatically to providea protection for transformer or on load tap changer.
Model Explanation
QJ: □-□
QJ: gas relay
□:Serial number
□:Nominal dia mm
Voltage Regulation Model
I.Main specifications
Type | fig | Installing dimension | Remarks | |||||||||||
D | D1 | D2 | D3 | D4 | B | L1 | L | H1 | H2 | n | d | |||
QJ4-25 | fig1 | 25 | 85 | 115 | 31 | 56 | 200 | 206 | 210 | 150 | 4 | 14 | There are 4 binding posts that can be Connect the air box. (1) | |
QJ6 -25 | 25 | 85 | 115 | 31 | 56 | 200 | 206 | 186 | 141 | 14 | 2 binding posts, no gas alarm signal (2) | |||
QJ1-50 | fig2 | 50 | 130 | 56 | 100 | 120 | 160 | 168 | 216 | 156 | 4 | M12 | This product is an old model, rarely used except for maintenance, with 4 terminals. The trip contacts are connected in series, and there is no gas box interface. (3) | |
QJ1-80 | 80 | 130 | 85 | 110 | 120 | 160 | 168 | 216 | 156 | 4 | M12 | |||
QJ10-50 | 50 | 130 | 56 | 100 | 120 | 160 | 168 | 216 | 156 | 4 | M12 | This product is a replacement product of QJ1-50 and QJ1-80, with the same installation size,parallel connection of trip contacts, and air guide box can be installed. (4) | ||
QJ10-80 | 80 | 130 | 85 | 110 | 120 | 160 | 168 | 216 | 156 | 4 | M12 | |||
QJ3-50 | 50 | 125 | 125 | 185 | 223 | 160 | 4 | 14 | This product is used on oil-immersed transformers with fire extinguishing device, 6 terminals, and can be installed with gas guide box. (5) | |||||
QJ3-80 QJ12-80 | 80 | 160 | 160 | 185 | 240 | 160 | 4 | 18 | ||||||
QJ4-50 | 50 | 125 | 125 | 185 | 223 | 160 | 4 | 14 | 5 terminal posts, the trip contacts are connected in parallel, and the gas guide box can be installed. (6) | |||||
QJ4-80 | 80 | 160 | 160 | 185 | 240 | 160 | 4 | 18 |
Technical data
1、Working temperature:-30℃~95℃
2、Switch capacity:AC 220V 0.3ACOSφ≤0.6 DC220V0.3AS≤5×10-35
Type | QJ-80 | QJ-50 | QJ-25 |
Range of flow(m/s) | 0.7~1.5 | 0.6~1.2 | 0.8~1.2 |
Gas accumulaton | 250~300 | <250 |
Filling transformer oil into the relay, Pressurizing normal temperature 200Kpa, Continued200min and without any leakage.
Test Item | Voltage between Contacls | Woleage between terminal and earth | Voltage berween signal and tripping terminal |
Withstand power frequency voltage and time | 2000v/1min | 2000v/1min | 2000v/1min |
Our Advantage
* Big range of gas detection
* Low oil level alarm Removal function
* Probe detection
* Direct oil Display
* responsive
* Stable use
* Stainless-steel float,anti-aging,floats accurately